Description
Şişecam High Reflective Glass is Şişecam Flat Glass’ reflective solar control glass.
It can be used as monolithic and also it can be incorporated into Insulating Glass Unit with clear float glass or heat control coated glass.
Şişecam High Reflective Glass is Şişecam Flat Glass’ reflective solar control glass.
Advantages
Note:
The coated surface should be placed facing inside (surface no 2) of the Insulating Glass Unit.
Solar control glass is subjected to thermal breakage risks. In order to avoid thermal breakage risks, toughening or heat strengthening is recommended. When laminating Şişecam High Reflective Glass, all panes of the laminated glass should be either toughened or heat strengthened in order to avoid thermal breakage risks.
Şişecam High Reflective Glass is Şişecam Flat Glass’ reflective solar control glass.
It can be used as monolithic and also it can be incorporated into Insulating Glass Unit with clear float glass or heat control coated glass.
Şişecam High Reflective Glass provides solutions for facades of medium sized commercial buildings and industrial buildings where visual integrity is required.
Şişecam High Reflective Glass is manufactured by applying a silver reflective coating on one surface of the clear glass through LVC (Laminar vapor coating) process during the production of float glass.
Performance Tables
Şişecam High Reflective Glass is manufactured by applying a silver reflective coating on one surface of the clear glass through LVC (Laminar vapor coating) process during the production of float glass.
Coated Surface | Daylight (EN 410) | Solar Energy (EN 410) | Thermal Conductivity (U Value) W / m2K (EN 673) | |||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
Transmittance % | Reflectance Outdoor % | Reflectance Outdoor % | Absorption % | Direct Transmittance % | Solar Factor % | Shading Coefficient | 12mm Airspace | 16 mm Airspace | ||||
Dry Air | Argon | Dry Air | Argon | |||||||||
Single Glazing – 4 mm | ||||||||||||
#2 | 34 | 44 | 31 | 24 | 45 | 51 | 0,59 | 5,8 | ||||
Single Glazing – 6 mm | ||||||||||||
#2 | 34 | 43 | 28 | 29 | 43 | 51 | 0,59 | 5,7 | ||||
Insulating Glass Unit With Clear Float Inner Pane | ||||||||||||
#2 | 31 | 44 | 30 | 36 | 34 | 42 | 0,48 | 2,8 | 2,7 | 2,7 | 2,6 | |
Insulating Glass Unit With Low-E Coated Glass (Low-E coating on the 3rd surface) Inner Pane | ||||||||||||
#2 | 30 | 44 | 38 | 39 | 23 | 30 | 0,34 | 1,6 | 1,3 | 1,3 | 1,1 |
The above figures are valid for IG units incorporating with 6 mm Şişecam High Reflective Glass outer pane, 12/16 mm air space and 6 mm inner pane. ● “Daylight” and “Solar Energy” properties are calculated with “TNO Science and Industry – WIS 3.01” program using spectral measurements in compliance with EN 410.
“U-value” is calculated with “TNO Science and Industry – WIS 3.01” program according to EN 673. The emissivity measurements used for calculations are in compliance with EN 673 (Annex A) and EN 12898.
Thermal stresses or building codes may require the use of heat-treated glass. This document is not an evaluation of the risk of glass breakage from thermal stresses. Please contact Şişecam Flat Glass to ensure the correct form of glass to be supplied for the structure.
Specifications, technical and other data are based on information available at the time of preparation of this document and are subject to change without notice.
Trakya Cam Sanayii A.Ş. cannot be held responsible for any deviation between the data introduced and the conditions on site. This document is only informative, in no way it implies an acceptance of the order by Trakya Cam Sanayii A.Ş.
Daylight Transmittance (%): The ratio of the visible spectrum (light) that is transmitted through glass.
Daylight Reflectance (outdoor) (%): The ratio of the visible spectrum (light) that is reflected outside by glass.
Solar Factor: The percentage of total solar radiant heat energy entering the room thorough the glass. The lower solar factor means better solar control.
Shading Coefficient: The ratio of solar factor of a particular glass type to the solar factor of 3 mm clear float glass, set in identical conditions. The lower shading coefficient means better solar control.
U value (W/m2K): A measure of the rate of heat loss of a building component. The lower U value means better heat control and more comfort in winter.
Quality
Şişecam High Reflektive Glass is manufactured in accordance with EN 1096 Glass in Building – Coated Glass.
The tolerances on nominal sizes are ± 5 mm. In addition to above data, other thickness and sizes can be applied. For more information, please ask for Şişecam Flat Glass.
Storage
Washing
Carrying and Handling (in the plant)
Cutting
Processes
Enameling
Tempering
Insulating Glass Unit (IGU) Production
Cleaning